Double-walled cylinder , IEC 60598-1 Annex K Temperature measurement

Categories Light Testing Equipment
Brand Name: KingPo
Model Number: IEC 60598-1 Annex K
Certification: Calibration Certificate
Place of Origin: China
MOQ: 1
Price: To be quoted
Payment Terms: T/T
Supply Ability: 50 pcs per month
Delivery Time: 7 working days
Packaging Details: safety carton pack or plywood box
Place of origin: Guangdong,China(mainland)
Standard: IEC 60598-1 Annex K
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Double-walled cylinder , IEC 60598-1 Annex K Temperature measurement

IEC 60598-1 Annex K Temperature measurement- Double-walled cylinder


Conform to IEC 60598-1 Annex K.1


The average ambient temperature in the draught-proof enclosure is taken to be the air temperature at a position near one of the perforated walls on a level with the centre of the luminaire. The temperature is usually measured by a thermocouple soldered to a metal mass of approximately 30 g shielded against radiation by a double-walled cylinder of polished metal open at the top and bottom.


Specifications

1. Material: stainless steel + brass

2.Brass weight :30g

3.Cylinder:The outer cylinder diameter is 50mm, the inner cylinder diameter is 20mm, and the height is 50mm


TESTING AND MEASURING EQUIPMENT/ALLOWED SUBCONTRACTING

IEC 60598-1:2014, A1:2017 Edition 8.1

Luminaires – Part 1: General requirements and tests


ClauseMeasurement/testingTesting / measuring equipment / material neededEquipment Classification
3.4Test of markingPiece of cloth / Water / Petroleum spiritR
4.4.4Lampholder pressure testTest caps / Pressure device / Torque driverR
4.4.5Voltage across lampholdersHigh voltage probe / OscilloscopeR
4.11.6Electro-mechanical contact systemLow voltage variable current power supply, voltmeter, high voltage transformerR
4.12.1 / 4.12.5Screws and connections (mechanical) and glands testingTest screwdriver or spanner / Test rodsR
4.13.1/4.13.4 4.13.6/4.21.4

Mechanical strength tests

Spring-operated impact test apparatus / Apparatus for ball impact tests Conditioning cabinet (e.g. freezer) / Angle measuring device / Weighting device / Tumbling barrel test equipment

R

4.14.1/4.14.2

4.14.3

Adjusting devices testingGlass test shelves / Weighting device / Test apparatus for adjustable devicesR
4.9.2/4.18.1Insulating linings and sleeves tests / Resistance to corrosionHeating cabinet, humidity cabinet, megaohmeter, high voltage transformerR
4.18.2/Annex FStress corrosionCloseable glass vessel / test solution / Heating cabinet / Facilities to wash samples after testR
4.20Rough service luminairesVibration test equipmentS
4.22Attachment to lampsWeighing deviceR

4.24/Annex P


Photobiological hazard: UV radiation, retinal blue light hazard

  • UV radiation test instruments / retinal blue light hazard test instruments (Equipment List of IEC/TR 62778
  • Goniophotometric measurement system

S


S

4.26Short circuit protection testTest chain / Weighting deviceR
4.28Fixing of thermal sensing controlsTemperature change test instruments in accordance to IEC 60068-2-14, test NaS
5.2.10.1Pull and torque tests on cord anchorageCord anchorage tests apparatus (pull and torque)R
5.3Internal wiring dimensionsMicrometer / Equipment for insulation thicknessR
5.4Test of conductors having a reduced cross-sectional areaThermometer / Thermocouples / Ammeter / Adjustable resistive loadR
7.2.3Earth continuity testEarthing test equipmentR

8.2.5

8.2.7

Protection against electric shock tests / Capacitor discharge

Standard test finger (IEC 60529) / Unjointed test finger

Voltmeter / oscilloscope

R


9.2.0Solid object proof luminaire testingIP 3X (2,5 mm) / IP 4X (1 mm) probesR
9.2.1 / 9.2.2Dust proof luminaire testsApparatus for proving protection against dustR
9.2.3,4,5,6,7, 8,9Water proof luminaires testingApparatus for protection against water testsR
9.3.1Humidity testsHumidity cabinetR
10.2.1Insulation resistance testsMegaohmmeterR
10.2.2Electric strength testsHigh voltage transformerR
10.3.1Leakage current testingLeakage current testerR
11.2.1Creepage distances and clearances measurementsDigital calliper (or equivalent) / OscilloscopeR
12.3.1Endurance testsThermal cabinet (35°C) / Endurance test equipment / Multimeter / WattmeterR

12.4.1


Thermal tests

Draught-proof enclosure (25°C) or alternative chamber/room / Thermometer / Thermocouples / Voltage stabilizer / Multimeter / Wattmeter

R

12.5.1e)

Annex C

Fig. C3


Abnormal operation testing


Test circuit for metal halide luminaires


R


12.7.2

Test for luminaires with temperature sensing controls internal/external to the ballast or transformerRelevant equipment of clauses 15.3 and 20.6, Equipment List of IEC 61558-1:2005

R

13.2.1Resistance to heat testHeating cabinet / Ball pressure test apparatus (see also CTL DSH 391 D)R
13.3.1Resistance to flame testNeedle flame test apparatusR
13.3.2Resistance to ignition testingGlow-wire test apparatusR
13.4.1Resistance to tracking testProof tracking test deviceR
14Screw terminalsTorque drivers, test cables, pull device, micrometer, timerR
15Screwless terminalsPull device, variable current source, voltmeter, heating cabinet, timer, test cablesR