Sign In | Join Free | My xxjcy.com
xxjcy.com
Products
Search by Category
Home > Lamp Holders & Lamp Bases >

7006-47C For G5 Lampholders , 7006-60C For G13 Lampholders

Categories Light Testing Equipment
Brand Name: KingPo
Model Number: IEC60598-1-clause 4.4.4
Certification: Calibration Certificate
Place of Origin: China
MOQ: 1
Price: To be quoted
Payment Terms: T/T
Supply Ability: 50 pcs per month
Delivery Time: 7 working days
Packaging Details: safety carton pack or plywood box
Place of origin: Guangdong,China(mainland)
Standard: IEC60598-1-clause 4.4.4
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

7006-47C For G5 Lampholders , 7006-60C For G13 Lampholders

7006-47C for G5 lampholders , 7006-60C for G13 lampholders


G5 lampholders Conform to IEC60061-3- 7006-47C (The end of the gauge has an M6 thread that can be connected to the push-pull gauger)

G13 lampholders Conform to IEC60061-3-7006-60C (The end of the gauge has an M6 thread that can be connected to the push-pull gauger)


Lampholders for a fluorescent lamp, with a test-cap in position, are subjected, for 1 min, to a pressure applied to the centre of the cap in the direction of its axis of:
– 15 N for G5 lampholders;
– 30 N for G13 lampholders;
– 30 N for lampholders for single-capped fluorescent lamps (G23, G10q, GR8 etc.).
Values for other lampholders are under consideration.
NOTE For these tests, caps from standardized lamps can be used as the test caps.
After the test, the distance between the holders shall comply with the relevant standard sheet of IEC 60061-2 and the lampholder shall show no damage. The test-cap for this test shall comply with the following standard sheets in IEC 60061-3:
7006-47C for G5 lampholders,
7006-60C for G13 lampholders,
test-caps for other lampholders are under consideration.
After the test on lampholders for single-capped fluorescent lamps, the lampholder shall not have moved from its position and the fixing device shall show no permanent deformation, so that the lamp, when reinserted, will come in its intended position.

Quality 7006-47C For G5 Lampholders , 7006-60C For G13 Lampholders for sale
Send your message to this supplier
 
*From:
*To: KingPo Technology Development Limited
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0