The Shaffer 30"-1000psi Diverter, corresponding to the FH76-7 model, is a critical well control device engineered for high-reliability pressure management in oil and gas drilling operations. Designed in compliance with API Spec 16A and NACE MR 0175/ISO 15156 standards, it integrates annular blowout prevention and diversion capabilities, serving as an indispensable component in surface and sub-surface well control systems.
The diverter operates on hydraulic actuation with supplementary well pressure assistance:

| Items | Technical Parameters |
|---|---|
| Specifications and Models | FH76-7 |
| Weight kg | 12,500 |
| Height H mm | 1668.4 |
| Center of Gravity h mm | 755 |
| Performance Rating | PR1 |
| Path | 762mm (30") |
| Rated Working Pressure | 6.9 MPa / 1,000 psi |
| Hydrostatic Test Pressure | 10.5 MPa / 1,500 psi |
| Hydraulic Chamber Strength Test Pressure | 15.5 MPa /2,250 psi |
| Rated Hydraulic Control Pressure (MPa/psi) | 10.5 MPa /1,500 psi |
| Recommended Hydraulic Pressure (MPa/psi) | ≤ 10.5 MPa /1,500psi |
| Maximum Working Pressure When Closing Empty Well (MPa/psi) | 10.5/1,500 |
| Rated Range | 0 "-20" |
| Maximum Amount of Oil Needed to Open | 210L |
| Maximum Amount of Oil Needed to Close | 461L |
| Specification For Hydraulic Oil Outlet Connection | Female NPT 2 "or NPT 1" (Adapter) |
| Non-Metal Seal Temperature Rating | BGD (-18℃ ~ 121℃) |
| Metal Body Temperature Level | T20/250 (-29℃ ~ 121℃) or T20/350 (-29℃ ~ 177℃) |
Instructions:
The blowout preventer is designed and manufactured in accordance with API Spec 16A.
The metal material inside the blowout preventer that comes into contact with the well fluid meets the requirements of NACE MR 0175/ISO 15156 for operating in acidic conditions.
|