SC(B)11-10kV Epoxy Resin Casting Dry Type Power Transformer

Categories Cast Resin Dry Type Transformers
Insulation material: Epoxy Resin
Weight: Varies by rating
Standards compliance: IEC 60076, IEEE C57.12.01
Voltage rating: 3.6, 6.3, 6, 10, 10.5, 11kV
Protection class: IP23 or higher
Temperature rise: Up to 150°C
Type: Dry-type Transformer
Certification: CE
Place of Origin: China
Delivery Time: Est. 15 days
Packaging Details: Wooden crates on pallets
Brand Name: JNCN
Model Number: SC(B)
MOQ: 1
Supply Ability: 5,000 Units per Year
Phase: Three-phase
Noise level: Below 65 dB
Cooling method: Air-cooled
Frequency: 50/60 Hz
Power rating: Up to 5000 kVA
Installation type: Indoor/Outdoor
Application: Industrial, Commercial, Renewable Energy
Company Info.
JNCN Power
Verified Supplier
View Contact Details
Product List
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

SC(B)11-10kV Epoxy Resin Casting Dry Type Power Transformer

SC(B)11-10kV Epoxy Resin Cast Dry-Type Transformer

The SC(B) series is a high-performance, three-phase resin-cast dry-type transformer designed as a superior, fire-safe replacement for traditional oil-immersed units. Fully compliant with IEC60076 standards, it features a compact, lightweight design with low noise and loss levels. Engineered for maximum reliability in high-demand urban infrastructure, this maintenance-free solution offers exceptional mechanical strength, anti-fouling properties, and flame resistance.

Ideal Applications
  • Infrastructure: Subways, airports, railway stations, tunnels, and underground power stations.
  • Commercial: High-rise buildings, business centers, hospitals, and hotels.
  • Industrial: Test chambers and combined transformer substations.
Technical Features & Performance
Intelligent Temperature Control & Protection

Our transformers feature a sophisticated monitoring system to ensure stable operation under all load conditions:

  • Real-time Monitoring: PTC temperature sensors are installed at the hottest points (top of the low-voltage windings) to provide precise measurement.
  • Automatic Protection: The controller triggers an Alarm Signal during overloads and an Automatic Trip if temperatures exceed safety thresholds.
  • Smart Cooling: Automatically manages cooling fans based on winding temperatures to optimize energy efficiency.
  • Remote Display: Supports remote temperature display and control (up to 20m for control; up to 100m with compensation conductors).
Robust Enclosure (Shell Protectors)

We provide high-quality protection options tailored to your installation environment:

  • Material Options: Durable Stainless Steel or Aluminum Alloy.
  • IP20 Rating: Prevents entry of solid foreign objects (>12mm), providing essential safety for indoor settings.
  • IP23 Rating: Features rain-proof protection (up to 60° angle), making it suitable for specialized outdoor operations.

Note: Using an IP23 enclosure may affect cooling capacity by 5% to 10% depending on the unit size.

Model Nomenclature
SC (B) 11 - □ / □
S: Three-Phase
C: Resin Insulated (Cast)
(B): Low-Voltage Foil Winding
11: Performance Level Designator
□: Rated Capacity (kVA)
□: Voltage Rating (kV)
Technical Parameters
Rated capacityVoltageBonding Group LabelNo-load lossLoad lossNo-load currentImpedance voltage
High voltage (kV)High voltage tap range (%)LV (kV)
306
6.3
6.6
10
10.5
11
20
± 2 * 2.5
±5
0.4


Dyn11
Yyn0

1907102.54.0
5027010002.0
6332511801.8
8037013801.5
10040015701.4
12547018501.3
16054021301.3
20062025301.2
25072027601.1
31588034701.0
40098039901.0
500116048800.9
630134058800.9
630130059600.96.0
800152069600.8
1000177081300.8
1250209096900.7
16002450117300.7
20003050 (South Network)
3320 (International)
144500.6
25003600 (South Network)
4000 (International)
171700.6
16002450129600.78.0
20003050 (South Network)
3320 (International)
159600.6
25003600 (South Network)
4000 (International)
188900.6
Ordering Guide for SC(B) Series Dry-Type Transformers

To provide you with an accurate quotation, please provide the following technical specifications when placing an order or inquiry:

Technical ParametersSpecifications / Options
Rated Capacity (kVA)[Please specify]
High Voltage (HV) Rating (kV)□ 10 □ 35 □ Others: ______
HV Tapping Range (%)±2 * 2.5 □ Others: ______
Low Voltage (LV) Rating (kV)□ 0.4 □ Others: ______
Number of Phases□ Single-phase □ Three-phase
Frequency (Hz)□ 50Hz □ 60Hz
Vector Group□ Yyn0 □ Dyn11 □ Others: ______
Short-circuit Impedance (%)□ 4% □ 6% □ 8% □ Others: ______
Insulation Class□ Class F □ Others: ______
Cooling Method□ AN (Natural Air) □ AN/AF (Air Force) □ Others: ______
Protection Rating (IP)□ IP00 □ IP20 □ IP23 □ Others: ______
Enclosure Entry/Exit Method

□ Top In / Top Out (HS1)


□ Bottom In / Top Out (HS2)


□ Bottom In / Bottom Out (HS3)


□ Side Entry/Exit

Operational Environment

□ Altitude 1000m


□ Ambient Temperature: ______

Temperature Control System[Please specify requirements for installation]
Order Quantity[Please specify]
Required Delivery Date[Please specify]
Additional Requirements[Please specify any other customized requests]
Factory Acceptance Tests (Routine Tests)

Every transformer manufactured at our facility undergoes a series of rigorous routine tests to ensure full compliance with international standards and guaranteed performance before dispatch:

  1. Voltage Ratio Measurement & Vector Group Verification: Ensures the transformation ratio and phase relationship meet design specifications.

  2. Winding Resistance Measurement: Checks the integrity of the conductive path and connections.

  3. Insulation Resistance Test: Verifies the dielectric strength and quality of the insulation system.

  4. Separate-Source Voltage Withstand Test (Applied Voltage Test): Tests the insulation between windings and to the earth.

  5. Induced Overvoltage Withstand Test: Validates the turn-to-turn and layer-to-layer insulation integrity.

  6. No-load Loss & No-load Current Measurement: Evaluates core performance and energy efficiency at zero load.

  7. Short-circuit Impedance & Load Loss Measurement: Assesses efficiency and performance under rated load conditions.

  8. Partial Discharge (PD) Measurement: A critical test for dry-type transformers to ensure long-term insulation reliability and detect any internal defects.

Why Choose JNCN Power Dry-Type Transformers?
  • Fire Resistant: Self-extinguishing epoxy resin ensures high safety in densely populated areas.
  • Maintenance-Free: No oil leakage or periodic oil testing required.
  • High Reliability: Manufactured in our 2026 modernized facility with CE certification and rigorous vacuum casting processes.
  • Export-Grade Delivery: Every unit is secured with high-standard packaging for global shipping.
Quality SC(B)11-10kV Epoxy Resin Casting Dry Type Power Transformer for sale
Send your message to this supplier
 
*From:
*To: JNCN Power
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0