Sign In | Join Free | My xxjcy.com |
|
Categories | Vehicle Loop Detector |
---|---|
Brand Name: | WONSUN |
Model Number: | WSTV-410 |
Certification: | CE, ISO, SGS |
Place of Origin: | China |
MOQ: | 1PC |
Price: | negotiation |
Payment Terms: | T/T,Western Union,Money Gram, Trade Assurance,Paypal etc., |
Supply Ability: | 1000 Sets/Month |
Delivery Time: | 3-7 working days after received your payment |
Packaging Details: | Packed in bubble wrap firstly, and then reinforced with carton for outer packing. |
Supply voltage: | 24V 12V |
Signal holding time: | Unlimited |
Sensitivity: | Adjustable in 3 increments |
Operating temperature: | 220℃ to +65℃ |
Reaction time: | 100ms |
Size of Housing: | 78x36x85 mm |
Company Info. |
Shenzhen Wonsun Machinery & Electrical Technology Co. Ltd |
Verified Supplier |
View Contact Details |
Product List |
Vehicle Loop Detector Parking Barrier Gate with high speed , CE ISO SGS Approval
Quick Detail:
Name: vehicle loop detector
The loop detectors must only be placed in dry rooms or control cabinets that are protected against
all types of moisture and wetness. A distance of at least 10 mm from other devices must be maintained
on each side. The ambient temperature must not exceed 65° C. The installation of the induction
loop is described in other operating instructions.
Applications:
The WSTV-410 vehicle loop detector is a double channel inductive loop detectors. The principle is based on a change in the inductance within the loop which is caused by the metallic components of passing vehicles. The changes are picked up and evaluated by a microprocessor. Ease of use thanks to automatic calibration when the operating voltage is applied.
Specifications
Supply voltage: 230V AC , 115V AC, 24V DC/AC, 12V DC/AC
( See the label on the detector)
Voltage tolerance AC: +10% / -15%
Voltage tolerance DC: ±15%
Power Consumption: 4.5VA
Output relays: 240V/5A
Operating temperature: -20°C to +65°C
Storage temperature: -40°C to +85°C
Frequency range: 20 kHz to 170 kHz
Reaction time: 100ms
Signal holding time: Unlimited
Sensitivity: Adjustable in 3 increments
Loop inductance: Total loop plus connection wiring: 50μH to 1000μH.
Ideal is 100μH to 300μH
Loop connection wiring: Maximum length 20 meters, twisted at least 20 times per meter
Size of Housing: 78x40x108 mm (L x W x H)
![]() |