Stable Performance Impact Mechanical Testing Machine High Degree Of Automation

Categories Mechanical Testing Machine
Brand Name: MITECH
Model Number: MJB-W
Certification: CE
Place of Origin: China
MOQ: 1 piece
Price: USD
Payment Terms: Western Union, T/T Paypal
Supply Ability: 500 piece per day!
Packaging Details: standard export carton
Tilt angle: 150°
Bearing span: 40mm
Angle of support on Sample bearing:
Angular accuracy: ±0.1°
Dimensions (mm): 2124×600×1340mm
Total Weight: 450kg
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    Stable Performance Impact Mechanical Testing Machine High Degree Of Automation


    Stable Performance Impact Mechanical Testing Machine High Degree Of Automation


    Mitech MJB-W micro-control series impact testing machine, throuth the computer control pendulum movement, for metal, which can be for metal, non-metallic and composite materials under dynamic load resistance to the impact of the test. It uses the computer control, with stable performance and high degree of automation, integrated operation. Its structure is strong, simple structure, high efficiency. The machine is widely used in steel, steel pipe and other toughness of ferrous metals and alloys of its anti-pendulum impact performance of the accurate measurement,It is the necessary professional precision testing equipment for improving production efficiency and saving production costs.

    Technical Parameters


    Technical ParametersMJB-W300BMJB-W500B
    Impact energy150J,300J250J,500J
    Impact speed5.2m/s5.4m/s
    Tilt angle150°
    Bearing span40mm
    Angle of support on Sample bearing
    Angle of impact tool30±1°
    Impact knife thickness16mm
    Bearing fillet radiusR1~1.5mm
    Impact blade radiusR2~2.5mm
    Angular accuracy±0.1°
    Pendulum torque80.3848N.m,160.7695N.m
    Pendulum rotation center to the impact point (test center) distance750mm800mm
    Sample size10×10(7.5,5,2.5)×55mm
    Power180W
    Power supply380V
    Dimensions (mm)2124×600×1340mm
    Total Weight450kg

    Working Principle


    The hemispherical punches of the impact testing machine impact and pass through the specimen at a certain speed and measure the energy consumed by the punch to evaluate the impact resistance of the specimen.

    Features


    • Widely used in metallic and non-metallic processing industry, quality testing in quality inspection departments , scientific research in higher education institutions and other fields;
    • It adopts single-chip control,and tilt pendulum, hanging pendulum, impact, are all under the computer control, and automatic tilt pendulum, with high efficiency, especially for continuous impact test;
    • Zero adjustment, calibration, save, etc. without any analog adjustment link, the control circuit is highly integrated;
    • The system can realize the automatic calibration of the indication accuracy;
    • At the end of the test, the test data is automatically saved for later retrieval.
    • With features of novel shape, strong structure, high reliability, simple operation;
    • Can be directly observed in the display, intuitive readings, high test efficiency;
    • Using a single support column structure, cantilevered hanging pendulum, U-shaped pendulum hammer, with stable performance and high precision;
    • Impact knife with screw mounting fixed, easy to replace;
    • Sample simple beam support can quickly replace the sample, easy to operate;
    • Take the brand computer, Chinese and English Windows operating platform, menu prompts, mouse operation, with fast running, clear interface, simple operation and so on, to meet the needs of different materials test;
    • Real-time print output test data, user-friendly data processing, analysis and so on;
    • Equipped with safety protection pin, safety protection network, etc., to ensure safety test;
    • Consistent with GB, ISO, ASTM, DIN and other relevant domestic and foreign standards.

    Scope of application


    It is widely used in the accurate determination of pendulum impact resistance of ferrous metals and alloy materials, such as steel, steel pipe, etc..


    Applications

    • Quality control link of Metal processing manufacturing
    • Quality control link of nonmetal manufacturing industry
    • Teaching experiment of scientific research in Institutions of higher learning
    • Material analysis test of scientific research institutions
    • Quality inspection link of Quality inspection department

    Working Conditions

    • Operation Temperature:Ambient temperature~45℃;
    • Relative humidity:20%~80%;

    l In an environment free from vibration,corrosive medium and high magnetic field

    l Installed on a flat basis.

    • Power supply voltage fluctuation does not exceed 10% of rated voltage.

    Configurations


    Configuration instructionsNO.NameQTY.Remarks
    Standard Configuration1Testing machine main unit1
    2Measurement and control software1
    3Pendulum2
    4Bearing adjuster1L=40
    5Sample centering device1
    6Disassembler1
    7Feet screw4
    8Adjust the oblique iron4
    9Inside the hex wrench1S=12
    10Safety protection device1
    11Automatic positioning mechanism1
    12Photoelectric Sensors1
    13Computer1With display
    14Printer1
    15Attchment files1

    Maintenance and care


    • Before using the instrument, please read the instruction manual carefully, understand the operation steps and precautions,to avoid the damage caused by improper operation or personal safety accident;
    • Testing machine is a large precision instrument, should pay attention to avoid water, moisture. Exposed workbench and attached parts should be coated with anti-rust oil to prevent rust;
    • It is forbidden to put samples before the pendulum hangs. Before placing the sample, make sure that the pendulum has been stalled and that the insurance pin has been ejected;
    • Should pay attention to check the use of jaw support, pendulum, etc. are reliable to live tight to prevent the test results inaccurate or accident occurred;
    • Pendulum shaft bearings at both ends of the factory has been refueling, users do not have to refuel, if it is repaired,then add 1-2 drops of sewing machine oil or watch oil, the rest of the power bearing plus Vaseline or butter;
    • If idle for a long time, at least once a week to prevent rust;
    • After the test, the pendulum to be placed in the vertical position, and the handle putter placed in the brake position;

    l Don’t disassemble the instrument without authorization, maintenance related matters please contact MITECH after-sale service department with 4000600280.


    Quality Stable Performance Impact Mechanical Testing Machine High Degree Of Automation for sale
    Send your message to this supplier
     