Sign In | Join Free | My xxjcy.com
xxjcy.com
Products
Search by Category
Home > Measuring & Analysing Instrument Stocks >

High Reliability Power Calibrator with KS803

Categories Power Calibrator
Place of Origin: China
Brand Name: Kingsine
Certification: ISO9001,CE
Model Number: KS803
MOQ: 1 set
Delivery Time: 15 working days
Payment Terms: T/T in advance ,L/C
Supply Ability: 50 sets/ month
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    High Reliability Power Calibrator with KS803

    High Reliability Power Calibrator KS803


    Voltage (AC) Output Shift:10V/30V/100V/300V/750V Auto switch


    Current (AC) Output Shift:100mA/1A/5A/10A/25A Auto switch


    Work power supply range:220VAC±15%, 50Hz


    PC connection:RS232


    Large LCD display, English pop-up menus in operations!


    Features &Function


    1. Capable of calibrating all kinds of indicating instruments such as DC meters,AC meters, phase meters,


    frequency meters, power meters, power factor meters, multimeters, energy meters and electric


    measurement transducers, etc. Automatic calibration mode and manual calibration mode are built-in of


    KS833.


    2. These built-ins are high precision standard sources that respectively relate to voltage, current, phase,


    power factor and harmonic.Capable of outputting standard voltage, current, phase, active power, cross-


    phase reactive power and true reactice power, make use of software to realize closed loop control on all


    outputs guaranteeing its low drift and its annual stability. Current generator provides the function of open-


    circuit protection and open-circuit alert in itself. While voltage generator possesses the function of short-


    circuit protection.


    3. Can freely output 2-31 times harmonics, including: Standard output at Grade 0.1 for 2nd-19th harmonics,


    and satandard output of Grade 0.2 for 20th-31st harmonics.


    4. Large LCD display, all English pop-up menus for these operations:①rotary encoder operation ② slight-


    touch keyboard operation ③operation under PC Windows System.


    5 . Built-in RS232 port, allows software upgrade without opening up the external box of the equipment; and


    calibrated data can be uploaded into PC computer at users’ convenience.


    6. The shock and impact resistance external box is made of high intensity aluminum alloy. Inside are


    reliable high-power heating radiator units, and the equipment is durable to use.


    Technical Data of KS803


    Voltage (AC) Output/Measure

    Shift

    10V/30V/100V/300V/750V Auto switch

    Adjusting range

    0 ... 120%

    Min Adjusting Unit

    Shift x 0.01%

    Resolution

    Shift x 0.01%

    Accuracy

    0.05%RG (RG abbr. range)

    Stability

    0.01%/1min

    Current (AC) Output/Measure

    Shift

    100mA/1A/5A/10A/25A Auto switch

    Adjusting range

    0 ... 120%

    Min Adjusting Unit

    Shift x 0.01%

    Resolution

    Shift x 0.01%

    Accuracy

    0.05%RG

    Stability

    0.01%/1min

    Power Output/Measure

    Min Adjusting Unit

    Shift x 0.01%

    Resolution

    Shift x 0.01%

    Accuracy

    0.05%RG (F>0.5)

    Stability

    0.01%/1min

    Frequency Output/Measure

    Range

    45.000...65.000Hz

    Min Adjusting Unit

    0.001Hz

    Accuracy

    0.01%RD

    Phase Output/Measure

    Range

    0.00° ... 359.99°

    Min Adjusting Unit

    0.01°

    Resolution

    0.01°

    Accuracy

    0.05°

    Power factor Output/Measure

    Output range

    -1 ... 0 ... +1

    Min Adjusting Unit

    0.0001

    Accuracy

    0.0005

    Harmonic Output/Measure

    Set range

    2 ... 31 times

    Content

    Voltage, Current≤30%( compared with Fundamental Wave)

    Harmonic output accuracy

    0.1%(2 ... 19 times, compared with Fundamental Wave)

    Resolution

    0.2%(20 ... 31 times, compared with Fundamental Wave)

    Harmonic Phase

    0.00° ... 359.99°

    Output Voltage and Current distortion

    <0.2%(non capacitance load)

    Max AC Output Load

    Voltage 25VA, Current 25VA

    Index measure reference condition

    Environment temperature

    22±1 °C

    Work temperature

    0°C ... 40°C

    Humidity range

    ≤85 %

    Work power supply range

    220VAC±15%, 50Hz

    Weight

    24KG

    Dimensions

    450(D)×180 (W)×380 (H) mm

    PC connection

    RS232


    Major functions:


    KS803

    KS813

    KS823

    KS833

    AC Standard Sources

    DC Standard Sources

    Harmonic Standard Sources

    Indicator Test

    Transmitter Test

    Energy Meter Test


    Note: Without the corresponding function modules.